Clean Room Solutions

Hospital Engineering Solutions

Our "All-In-One" 3 stage cooling, dehumidification, re-heating, recovery, automation and filtration unit is a compact but an efficient system built to last. It is 100% plug and play standalone ''one piece'' unit, which needs only ducts and power supply for its start up. In support of the health care process, HVAC systems are called upon to perform several vital functions that affect environmental conditions, infection and hazard control, and building life safety. MAX.E3-DH series units are designed and manufactured in accordance with all the major international standards.

EN 1886 | Ventilation for Buildings | Air Handling Units | Mechanical Performance: The standard is a part of a series of standards for air handling units, used for ventilation and air conditioning of buildings for human occupancy. It considers the mechanical performance of an air handling unit and will be supported by a standard for sections and components. This standard specifies test methods, test requirements and classifications for air handling units, which are supplying and | or extracting air, via ductwork, for ventilating | conditioning a part or the whole of the building.

[VDI 6022-1: 2011-07] Hygiene requirements for ventilation, air-conditioning systems and units:

  • All materials must comply with health requirements and prevent microbiological growth.
  • All units and components are easily accessible and equipped with lighting.
  • Continuous and complete condensate drainage.
  • Use of fans with access for cleaning.
  • Sandwich panel construction.
  • Low condensation tendency.
  • Smooth internal surfaces.
  • Grooves easily cleanable.
  • Bottom panel surface powder coated or made in stainless steel.
  • Sealing materials must be closed-cell type and not absorb moisture.
  • Hygienically manufacture, transportation and intermediate storage at the place of installation.

HTM 03-01: Specialized Ventilation for Healthcare Premises.

This document treats not only the ventilating and air-conditioning unit, but also the distribution system. And MAX.e3-DH is constructed in accordance with the general technical requirements of this memorandum.

MAX.e3-DH is an equipment specially developed for hospitals, where temperature and relative humidity have to be in narrow limits (±1oC/±2%) maintained. Thus, is designed to:

  • AHU Drainage System.
  • AHU's Layout.
  • Provision of Dampers.
  • Control System (Automation and Accessibility).
  • Sequence of Components that should be considered each as for it.


ASHRAE - HVAC design manual for hospitals and clinics, which provides in-depth design recommendations based on best practices, and presents proven, cost-effective, and reliable solutions that result in low maintenance cost and high reliability.